Part Number Hot Search : 
0J101 T6027T KBPC3510 1540CT MJE295 M1201 1N4759A 3C0R25FW
Product Description
Full Text Search
 

To Download B84299K0061 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 EMC filters
2-line filters
for installations and systems
Rated current 2 to 36 A
Series/Type: Date: B84299K0061 ... K0067 January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS' prior express consent is prohibited.
2-line filters for installations and systems
Power line filters for 1-phase systems with additional LF suppression Rated voltage 250 V DC/AC, 50/60 Hz Rated current 2 to 36 A Construction
2-line filter
Metal case
Polyurethane potting (UL 94 V-0)
B84299K0061 ... K0067
Features
Especially high differential-mode
insertion loss from 20 kHz upwards
Safe mounting by press-in nuts Space-saving design ENEC10 and UL approval
Applications
Switch-mode power supplies for traction,
safety systems, automation engineering
Power supplies Industrial electronics DC applications
Terminals
Litz wires
Marking Marking on component:
Manufacturer's logo, ordering code, rated voltage,
rated current, climatic category, date code
Minimum marking on packaging:
Manufacturer's logo, ordering code
Typical circuit diagram
LINE Blue L LOAD Blue L'
N Black
Please read Cautions and warnings and
Important notes at the end of this document.
N' Black
SSB0591-E-E
2
01/06
2-line filters for installations and systems
Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Overload capability (thermal) Leakage current lleak Climatic category (IEC 60068-1) 250 V DC/AC, 50/60 Hz
B84299K0061 ... K0067
Referred to 40 C ambient temperature 1414 V DC, 2 s (line/line) 2830 V DC, 2 s (lines/case) 1.5 * IR for 3 min per hour or 2.5 * IR for 30 s per hour At 230 V AC, 50 Hz For K0061 and K0062: 25/100/21 (-25 C/+100 C/21 days damp heat test) For K0063 ... K0067: 25/085/21 (-25 C/+85 C/21 days damp heat test) EN 133200, UL 1283
Approvals
Characteristics and ordering codes VR AC/DC V 250 IR A 2 4 6 10 16 25 36 Terminal cross section mm2 AWG 1.0 1.0 1.0 1.5 2.5 4.0 6.0 18 18 18 16 14 12 10 lleak mA < 3.5 < 3.5 < 3.5 < 3.5 < 3.5 < 3.5 < 10 Rtyp m 530 150 100 45 35 25 10 Approx. Ordering code weight kg 0.35 0.37 0.82 1.0 1.8 2.9 2.9 B84299K0061C000 B84299K0062C000 B84299K0063 B84299K0064C000 B84299K0065 B84299K0066 B84299K0067 Approvals
x x -- -- -- -- --
-- -- x x -- -- --
x = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
2-line filters for installations and systems
Dimensional drawings B84299K0061C000, B84299K0062C000 (2 and 4 A)
M4 x 6
B84299K0061 ... K0067
300.4
3 x litz wires AWG 18 (BU, BK, GNYE)
2 x litz wires AWG 18 (BU, BK)
51
7
30015
Load
Line
35015
7
45
Type
Marking
Length 65 mm 75 mm
B84299K0061C000 B84299K0062C000
SSB2097-8-E
B84299K0063 (6 A)
640.4 M4 x 6
460.4
3 x litz wires AWG 18 (BU, BK, GNYE)
2 x litz wires AWG 18 (BU, BK)
7 35015
30015
7.5
Load
Line
7
Marking
50
25.9 84.5
Please read Cautions and warnings and
Important notes at the end of this document.
Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp
SSB2098-G-E
4
01/06
67
2-line filters for installations and systems
B84299K0064C000 (10 A)
800.4 M4 x 8
B84299K0061 ... K0067
470.4
28 2 x litz wires AWG 16 (BU, BK) 7 35015 8 Load Line Marking o10 68.5 100.5 1 55
3 x litz wires AWG 16 (BU, BK, GNYE)
30015
Ground terminal M4 x 8
for shielding braid
or fixing stud
for cable clamp
7
SSB2099-P-E
Please read Cautions and warnings and
Important notes at the end of this document.
5
01/06
67
2-line filters for installations and systems
B84299K0065 (16 A)
1070.4 M4 x 6
B84299K0061 ... K0067
430.4
28
2 x litz wires AWG 14 (BU, BK) 9
3 x litz wires AWG 14 (BU, BK, GNYE)
45015
Load
Marking
100 132
SSB2100-W-E
Please read Cautions and warnings and
Important notes at the end of this document.
71
7 30015
Line
Ground terminal M4 x 8 for shielding braid or fixing stud for cable clamp
7
6
01/06
68
2-line filters for installations and systems
B84299K0066 (25 A)
1300.4 M5 x 7
B84299K0061 ... K0067
730.4
28
3 x litz wires AWG 12 (BU, BK, GNYE)
2 x litz wires AWG 12 (BU, BK)
7
8 Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
30015
68.5
Marking
153 183
SSB2101-5-E
Please read Cautions and warnings and
Important notes at the end of this document.
7
01/06
80020
Load
Line
7
85
2-line filters for installations and systems
B84299K0067 (36 A)
1300.4 M5 x 7
B84299K0061 ... K0067
730.4
28
2 x litz wires AWG 10 (BU, BK) 8
3 x litz wires AWG 10 (BU, BK, GNYE)
24015
68.5
Marking
153 183
SSB2102-D-E
Please read Cautions and warnings and
Important notes at the end of this document.
8
01/06
80015
Line
Load
7
Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
7
85
2-line filters for installations and systems
Insertion loss (typical values at Z = 50 )
B84299K0061 ... K0067
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
Filters for 2 A
100
B84299K0061C000
SSB0323-3
Filters for 4 A
100 dB 80
SSB0324-B
B84299K0062C000
dB 80
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Filters for 6 A
100 dB 80
SSB0325-J
Filters for 10 A
100 B84299K0064C000 dB 80
SSB0326-S
60
60
40
40
20
20
B84299K0063 0 10 4 10 5 10 6 Hz f 10 7
0 10 4
10 5
10 6
Hz f
10 7
Please read Cautions and warnings and
Important notes at the end of this document.
9
01/06
2-line filters for installations and systems
Insertion loss (typical values at Z = 50 )
B84299K0061 ... K0067
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 16 A
100 dB 80
SSB0327-1
Filters for 25 A
100 dB 80
SSB0328-9
60
60
40
40
20
20
B84299K0065
B84299K0066
7
0 10 4
10
5
10
6
Hz f
10
0 10 4
10
5
10 6
Hz f
10 7
Filters for 36 A
100 dB 80
SSB0329-H
60
40
20
B84299K0067 0 10 4 10 5 10 6 Hz f 10 7
Please read Cautions and warnings and
Important notes at the end of this document.
10
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective.
11
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
12
01/06


▲Up To Search▲   

 
Price & Availability of B84299K0061

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]